Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Case Rep ; 17(3)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38458763

RESUMO

We report a baby with neonatal herpes simplex virus (HSV) encephalitis concurrent with Rrhesus (Rh) incompatibility. He was delivered by a Ggravida 2 mother with a history of miscarriage in her previous pregnancy at a gestation age of 4 months. She had Bblood group 0 and Rrhesus negative. The baby was noticed to have jaundice on day one1 of life accompanied by generalised petechiae on the face and upper chest. A full blood picture revealed severe anaemia and severe thrombocytopaenia and HSV 1/2 IgM was positive. MRI of the brain showed multiple extensive haemorrhagic lesions on the frontal-temporal regions.


Assuntos
Encefalite por Herpes Simples , Herpes Simples , Complicações Infecciosas na Gravidez , Masculino , Recém-Nascido , Lactente , Gravidez , Feminino , Humanos , Herpes Simples/complicações , Herpes Simples/diagnóstico , Herpes Simples/tratamento farmacológico , Encefalite por Herpes Simples/complicações , Complicações Infecciosas na Gravidez/diagnóstico , Simplexvirus
2.
BMC Pediatr ; 24(1): 114, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350890

RESUMO

BACKGROUND: Neonatal jaundice is a condition caused by elevated levels of bilirubin in the bloodstream. Laboratory determination of serum bilirubin concentration by total serum bilirubin (TSB) test is still considered as gold standard for clinical guidance and practice. In developed countries, diagnosis of neonatal jaundice is shifting towards point-of-care medical devices. BiliDx is a device developed to allow a fast, blood-based determination of bilirubin levels at the point of care. This study aimed to determine the accuracy of the BiliDx device relative to a standard laboratory total serum bilirubin to diagnose and monitor jaundice among neonates admitted at Muhimbili National Hospital (MNH). MATERIAL AND METHODOLOGY: This was a prospective hospital-based observational study conducted at the Neonatal Ward - MNH, Dar-es-Salaam, Tanzania from November 2022 to January 2023. A total of 180 neonates admitted at the neonatal ward with jaundice and whose parents consented were enrolled in the study. Blood samples were collected; 2 ml of venous blood into the vacutainer bottle for standard laboratory measurement of total serum bilirubin (TSB) and 25µL blood collected into a transfer pipette tube and applied to BiliDx. STATA version 15.1 was used for data analysis. RESULTS: Out of 180 neonates, 39.4% (71/180) had birth weight between 1500 - 2499.9 g, approximately 2/3rd (120/180) were preterm, 92/180 (51.1%) were males and 100/180 (55.6%) were undergoing phototherapy treatment the moment sample taken. The mean bilirubin concentration was 92 mmol/l for BiliDx and 118 mmol/l for standard laboratory TSB. The minimum and maximum values obtained with BiliDx were, 3.4 and 427.5 mmol/l respectively, compared with 10.7 and 382.1 mmol/l using standard laboratory TSB. A linear relationship and correlation coefficient of 0.8408 (p = 0.000) between BiliDx and standard laboratory TSB was found. The regression analysis showed the presence of constant error [coefficient of BiliDx/slope = 0.91, 95% CI (0.82-0.99), p = 0.000] and random error exclusively [coefficient of constant/y-intercept = 48.52, 95%CI (37.70-59.34), p = 0.000]. The Bland-Altman plot showed an acceptable mean difference of 39.1mmol/l, limits of agreement of -48.3mmol/l to 126.4mmol/l, and 179 points (179/180 = 99.4%) lying inside the limits of agreement. CONCLUSION: The results support the use of BiliDx for rapid and accurate testing of elevated levels of bilirubin in the bloodstream among neonates since 99.4% of the differences between BiliDx and standard laboratory TSB lie between the lines of agreement.


Assuntos
Icterícia Neonatal , Icterícia , Recém-Nascido , Masculino , Humanos , Feminino , Icterícia Neonatal/terapia , Bilirrubina , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Icterícia/diagnóstico , Fototerapia , Hospitais , Triagem Neonatal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...